Kuppersbusch USA KD 6500.1 User Manual

Browse online or download User Manual for Cooker hoods Kuppersbusch USA KD 6500.1. Kuppersbusch USA KD 6500.1 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
KD 6500.1
KD 9500.1
GB
Instructions Booklet
F
Mode d’emploi
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - KD 9500.1

KD 6500.1KD 9500.1GBInstructions Booklet FMode d’emploi

Page 2

10 GBActive carbon filter• OperationThe activated charcoal filter is only fitted in recirculation type hoods. It will retain odoursuntil it becomes

Page 3

11FRLISEZ BIEN CETTE FICHE AVANT D’INSTALLER LA HOTTEAVERTISSEMENT - POUR MINIMISER LE RISQUE D’UN FEU DE GRAISSE SUR LA TABLEDE CUISSON : Ne jamai

Page 4

12 FRWARNING• Le système d’évacuation DOIT sortir à l’extérieur.• N’ÉVACUEZ PAS le conduit soit dans une mansarde soit dans un espace enferm

Page 5

13FRAVERTISSEMENTEn perçant un mur veillez à ne pas perforer un autre fil électrique.Une hotte à évacuation extérieure doit être raccordée

Page 6

FR14INSTALLATIONCette hotte est destinée à être installée au mur, au dessus d’un plan de cuisson. Ellepeut être utilisée en version évacuation (raccor

Page 7 - Fixing the canopy

FR 15hauteurs disponibles de la cheminée supérieure.d) Marquer sur la paroi les centres des alésages de l’étrier.Réalisation trous de fixation 1:a)

Page 8

FR16Connexion filtrante• L’air filtré est réintroduit dans le milieu au moyen des deux grilles latérales en plastiqueG présentes sur le demi-tube supé

Page 9 - MAINTENANCE

FR 17ENTRETIENUn entretien constant garantit un bon fonctionnement et un bon rendement dans le temps.Il est nécessaire de prêter une attention toute p

Page 10 - Cleaning

FR18des leds. En particulier:- 2 clignotements des leds Alarme saturation filtre au charbon actif ACTIVE.- 1 clignotement des leds Alarme saturation

Page 11

GGSICBRP1212ab

Page 13 - AVERTISSEMENT

S1S1111111RP1TGSA18_714_03RP1TGSA18_714_03G2SI2C643587

Page 14 - INSTALLATION

T1 T2 T3 T4 T5910 1112

Page 17 - ENTRETIEN

436001889 02 - 040210KÜPPERSBUSCH Hausgeräte AGKüppersbuschstraße, 16D - 45883 GelsenkirchenHausanschritt:Küppersbuschstr. 1645883 GelsenkirchenTelef

Page 18 - Nettoyage

3GBREAD AND SAVE THESE INSTRUCTIONSThe Installer must leave these instructions with the homeowner.The homeowner must keep these instructions for

Page 19

4 GBWARNING• Venting system MUST terminate outside the home.• DO NOT terminate the ductwork in an attic or other enclosed space.• DO NOT us

Page 20

5GBWARNINGSufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)of fuel burning equipment to prevent back

Page 21 - T1 T2 T3 T4 T5

6 GBINSTALLATIONThis canopy hood is designed to be fixed to any rigid vertical surface, over a gas orelectric hotplate and can be used either in the e

Page 22

7GB• Drilling fixing holes item 1:a) Mark a point on the vertical line at a distance from the cooking appliances of:d =1000 min (distance without s

Page 23

8 GB• Recirculation fitting• The filtered air is returned to the room through the two plastic side grills G on the upperchimney element S .• Connect t

Page 24 - 436001889 02 - 040210

9GBOPERATIONInstruction for UseControl Panel (fig. 9)The layout of the control panel is as follows:Button T1 = Turns the lighting system on and offB

Comments to this Manuals

No comments